INSTALLATION
Heater handover
12. Heater handover
Explain the functions of the heater to the user. Draw special atten-
tion to the safety information. Hand the operating and installation
instructions to the user.
13. Maintenance
MATERIAL LOSSES:
!
The spare parts may only be replaced (for example if
damaged) by a qualified contractor, using an original
Stiebel Eltron spare part.
14. Specification
14.1 Dimensions and connections
(27.4 cm)
10
CK 150-1 Trend / CK 200-2 Trend
g01
Air intake
g02
Air discharge
g03
Strain relief clamp / cable entry
8
| CK 150-1 / 200-2 Trend
(13.1 cm)
5
g01
g02
8 (20.2 cm)
(7 cm)
2
g03
14.2 Minimum clearances to hard surfaces
WARNING: Fire
Combustible materials such as furniture, papers,
clothes and curtains must be kept at least 3 feet (0.9 m)
from the heater.
Never place any flammable, combustible or insulating
objects or materials, such as laundry, blankets, maga-
zines, containers with floor polish or gasoline, spray
cans or similar on the heater or in direct proximity to
it.
NOTE:
Required minimum clearance from the floor to the
bottom of the heater:
United States: 4˝ (10 cm)
Canada: 24˝ (61 cm)
ANY HARD SURFACE
minimum
4
minimum
4
USA
The images above show minimum allowed clearances be-
tween the installed heater and any hard surfaces.
For installations in the United States, we recommend mount-
ing the heater 6-8˝ (15-20 cm) off the floor.
CAUTION: Injury
!
Maintain the minimum clearances.
minimum
12
minimum
4
minimum
24
Canada
FLOOR
minimum
20
FLOOR