Installation instructions
DOP48*963D*
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location
BTU Rate
LF
LR
RF
RR
CF
CR
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location
BTU Rate
LF
LR
RF
RR
CF
CR
26 English
DG68-01554A-00_IM_DOP48T960DS, DOP48T963DS_DA_EN+MES+CFR.indb 26
DG68-01554A-00_IM_DOP48T960DS, DOP48T963DS_DA_EN+MES+CFR.indb 26
Ori ce Size [mm]
16,000
In 0.46 / Out 0.78*2
15,000
1.04 / 0.50
15,000
1.04 / 0.50
15,000
1.04 / 0.50
16,000
In 0.46 / Out 0.78*2
9,500
0.78 / 0.50
Ori ce Size [mm]
18,000
In 0.70 / Out 1.27*2
16,000
1.60 / 0.68
16,000
1.60 / 0.68
16,000
1.60 / 0.68
22,000
In 0.85 / Out 1.36*2
9,000
1.20 / 0.61
Step 9. Install the anti-tip device
WARNING
•
To reduce the risk of tipping, the appliance must be secured by properly
installing the anti-tip device packed with the appliance.
•
All ranges can tip, resulting in personal injury.
Tipping ranges can cause burns from spills, personal injury, and/or death.
•
•
To prevent accidental tipping, install and check the anti-tip bracket following
the instructions and template supplied with the bracket.
An anti-tip bracket and screws, installation
instructions, and template are shipped with
every range (PN 114475). The instructions
include information necessary to complete
the installation of the anti-tip bracket. Read
and follow the instructions on the sheet
and use the template for anti-tip bracket
installation. If not properly installed, the
Anti-Tip Foot
range could be tipped by you or a child
(location varies)
standing, sitting, or leaning on an open oven
door.
Anti-tip
bracket
Anti-Tip Foot
2023-07-05 오후 2:19:26
2023-07-05 오후 2:19:26