ATTENTION:
Please observe the following rules when installing the heat pump:
1. Any addition of chemicals must take place in the piping located downstream from the heat
pump.
2. Always place the heat pump on a solid foundation and use the included rubber mounts to
avoid vibration and noise.
3. Always hold the heat pump upright. If the unit has been held at an angle, wait at least 24
hours before starting the heat pump.
5.1 Heat pump location
The unit will work properly in any desired location as long as the following three items are present:
The unit may be installed in virtually any outdoor location as long as the specified minimum distances to other
objects are maintained (see drawing below). Please consult your installer for installation with an indoor pool.
Installation in a windy location does not present any problem at all, unlike the situation with a gas heater (including
pilot flame problems).
ATTENTION: Never install the unit in a closed room with a limited air volume in which the air
expelled from the unit will be reused, or close to shrubbery that could block the air inlet. Such
locations impair the continuous supply of fresh air, resulting in reduced efficiency and possibly
preventing sufficient heat output.
See the drawing below for minimum dimensions.
5.
Location
and
5.
5.
Location
Location
and
and
1. Fresh air
2. Electricity
3. Swimming pool filters
- 17 -
connection
connection
connection