7.0 USER CALIBRATION

+
The EEWB330B Balancer features a User Calibration
which requires only a few minutes to complete. The
operator can electronically calibrate the rotating masses
on the machine; which is called User Calibration.
Perform this procedure when the balancer has been
moved, disturbed, or whenever accuracy is questioned.
If the calibration process fails a service technician must
be called to perform a complete calibration.
A calibration run requires little more time than a regu-
lar balance run.
Figure 30c
Procedure;
— Balance a wheel (15" x 6,5"), as a NORMAL weight
— Press the "MODE" key and the "FINE" key together
The initial display reads "C 14", See Figure 30b.
— Press "ENTER" once to initiate procedure.
The display shows "CAL 1". See Figure 30c.
— Remove any cones or adapters from the shaft. See
When compete, the display shows "CAL 2". See Figure 30e.
— Mount the User Calibration Weight, refer to Figure
— After a few seconds the display equals C ---, Figure 30g.
The User Calibration was performed correctly.
Any (operator) error causes the program to exit. Un-
screw the Calibration weight from the fl ange and put it
back in its designated place for safe keeping.
EEWB330B
mode, to less than 5 grams per plane.
for 5-7 seconds. See Figure 30a.
Figure 30d.
Note: Continue the spin until the unit beeps.
30f. Spin the shaft.