Selecting Operator Preferences; Fine Balancing Mode; Ounce/Grams Conversion; Rim Diameter In Millimeters - Snap-On EEWB330B Manual De Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.4 SELECTING OPERATOR PREFERENCES

4.4.1 FINE BALANCING MODE

This balancer measures with the maximum precision
availa ble all the time, 1g / 0.05 oz, however values
below 5g / 0.25 oz are shown as zero while in the nor-
mal operating mode. Values exceeding 5g / 0.25 oz
are rounded to the amount of the nearest commercial
wheel weight.
Press the FINE button to advance to the display resolu-
tion between 5g / 0.25 oz and 1g / 0.05 oz.

4.4.2 OUNCE/GRAMS CONVERSION

When the machine is fi rst turned on it is preset to display
the imbalance in ounces.
Press the MODE button to advance to select ounces
or grams.
Select Enter to save selection.

4.4.3 RIM DIAMETER IN MILLIMETERS

The rim diameter is normally displayed in inches,
however if the value in millimeters is desired. Press
the MODE button until "PAX/mm" is NOT illuminated
to display in inches, when lit the unit displays in mm.
Figure 19
16

4.5 ENTER RIM PARAMETERS

4.5.1 Rim Distance (offset)

arm to the edge of the rim, touch the pointer to the
rim edge as illustrated in Figure 19 and hold steady
for about a second. The beeper will sound when the
distance and diameter values are calculated and en-
tered. Return the arm to its fully in and down position
on the balancer. Do not allow the measurement arm to
"dangle" down in front of the balancer
Figure 20
4.5.2. Measure/Enter rim width using rim width caliper.
Measure wheel where corrective clip-on weight would
be applied, Figure 20.
W
Figure 21
Press the Width entry key, Figure 21-W, and enter the
measured width by pressing +/- keys until the desired
value appears in the display.
Select Enter to save selection.
EEWB330B
- Move the rim offset
.

Publicidad

Tabla de contenido
loading

Tabla de contenido