Filtration Menu - Pentair ControlPro CPRO-1010 Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74

FILTRATION menu

This menu manages the filtration pump operation and programs.
FILTRATION
AUTO
FILTRATION P1/V2
10:00 => 18:00
FILTRATION P2/V1
22:00 => 23:00
FILTRATION P3/Vx
--:--
--:--
BOOST DURATION (V4)
2:00
ANTI FROST
1°C
The startup screen within the Filtration menu allows selecting one of the
operation modes for the filtration pump. These are different for Single
speed and Variable Speed pumps.
Single Speed Pumps
OFF = filtration is disabled
MANU = manual operation. Filtration will run for as long as no other mode
is selected
PROG = filtration will run during (up to 4) timeslots that can be defined
further down this menu.
AUTO = filtration runs in function of temperature. It will start at the start
of program 1 for a duration equaling the pool temperature in °C divided by
2 (26°C equals 13 hrs filtration/day). With the pool cover input 'closed' the
filtration time is further reduced by 50% (6.5hrs for 26°C)
Variable Speed Pumps
OFF = filtration is disabled
MANU = manual operation. After confirming with ENT select and confirm
V1 , V2, V3 or V4.
PROG = filtration will run during (up to 4) timeslots that can be defined
further down this menu. For each program the speed can be selected.
BOOST = filtration runs at V4 for a predefined time .It is not possible to
change the speed for the BOOST function. When finished, filtration will
return to the last mode that was active before the BOOST mode .
This menu allows programming up to 4 timeslots for the 'PROG' mode.
-Filtration start an stop times can be set
-For Variable Speed pumps for each of the 4 programs the speed can be
also selected.
-It is possible to overlap programs. If these programs contain different
speeds, V4 will have priority over V3, V3 over V2 and V2 over V1.
-Program 4 will only become visible when prog 3 is activated.
-To delete a program select and confirm the --:-- value for start and stop
time.
Boost duration (only valid for variable speed pumps) determines the
duration of the boost mode (see filtration modes)
Antifrost mode (when activated) will run the filtration pump for 20' every
2 hrs for as long as the water temperature is lower than the set value.
Speed 2 is fixed as filtration speed in antifrost mode in configurations with
a variable speed pump.
Select OFF to disable the Antifrost mode.