Hood Mounting Instruction; Directions For Use; Changing The Filter Cartridge - Nederman FilterCart Original Manual De Instrucciones

Ocultar thumbs Ver también para FilterCart Original:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
5

Hood mounting instruction

The Fume Extractor arm is already fitted. The hood must be fitted according to
the Figure 3, items A–D.
A.
Insert the hood into the swiveling arm, and fasten together.
B.
Adjust the swiveling arm to the correct tension.
C.
Ensure that the swiveling arm has the correct tension and can be easiliy
positioned.
D.
Fasten the blue hose into the hood and secure it using the tightening ring.
6

Directions for use

The unit is only intended for indoor use and is designed for extraction and
filtration of dust or welding fumes. It must not be used for extraction of fluids.
Figure 4 and the following list illustrates how to use the unit:
1.
Lever for adjusting the damper.
2.
Switches for fan and spotlight.
The hood of the extraction arm is to be positioned as close to the pollution
source as possible. The unit is to be moved from behind according to Figure 4,
item A and with the wheels unlocked. The extraction arm is to be positioned
with the wheels locked according to item B.
WARNING!
Work safety regulations. Risk of personal injury, fire or
explosion.
• The unit must not be used in an environment with danger of explosion or for
dust or gases in explosive concentrations.
• If the unit has been used for dust applications it must not be used for
welding fumes or grinding dust.
• The unit must not be used for extracting toxic substances.
• The unit must not be used without filter cartridge and casing.
7

Changing the filter cartridge

The filter cartridge is disposable and is to be thrown-away after use. The life of
the filter cartridge varies greatly depending on how the unit is used, how much
and what type of pollutants are collected.
Regularly monitor the unit's extraction capacity at the hood and change the
filter cartridge when the extraction capacity is too poor. Always check that
the hoses for the extraction arm and the fan inlet are not damaged before it is
decided to change the filter cartridge.
WARNING!
Risk of personal injury.
Use necessary personal safety equipment when replacing the filter cartridges.
Change the filter cartridge as follows (see also Figure 5):
1.
Disconnect the mains connection cable.
2.
Unlock the eccentric locks and remove the filter casing.
3.
Use the plastic bag which comes with the new filter cartridge and pull it
over the used cartridge. Fold the plastic bag under the cartridge.
FilterCart Original
144027(01)
EN
13

Publicidad

Tabla de contenido
loading

Tabla de contenido