Operation; For Low Pressure Inflation; Less Than 20 Psi; Inflation Of Items That Require - Campbell Hausfeld RP4200 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions

Operation

THIS UNIT REQUIRES THE USE OF AN EXTENSION CORD TO OPERATE.

FoR loW PRessuRe InFlAtIon -

InFlAtIon oF IteMs thAt RequIRe less thAn 20 PsI
1 . Plug a standard extension cord into the inflator's extension cord inlet .
2a . If inflating a low pressure tire, attach universal adapter to valve stem with the
locking lever in the open/up position . Be sure to press the universal adapter
onto the valve stem thread completely . Failure to do so could lead to loss of tire
pressure during this process .
b . If inflating a sports ball, insert a metal inflation needle into the universal adapter .
Make sure the needle is secure in the adapter .
3 . When the universal adapter is firmly in place, press the locking lever down ( see
Figure 4) .
4 . Turn pressure selector dial until the desired pressure field reads "LO" (LO setting is
just below 20 psi setting) . See Figure 5 .
5 . Press power button (see Figure 6) .
6 . When item reaches desired firmness, press power button again to stop inflation
(see Figure 6) . The actual pressure will then read on digital gauge .
7 . If more inflation is needed, repeat steps 5 and 6 .
8 . Remove metal inflation needle and store, or raise universal adapter's locking lever
and remove from valve stem .
Overinflation can be dangerous. Pay attention while inflating low
pressure items to prevent overinflation.
Do not allow inflator to run unattended while in "LO" setting.

FoR stAnDARD tIRe InFlAtIon -

InFlAtIon oF tIRes BetWeen 20 PsI AnD 99 PsI

1 . Plug a standard extension cord into the inflator's extension cord inlet .
2 . Attach universal adapter to valve stem with the locking lever in the open/
up position . Be sure to press the universal adapter onto the valve stem thread
completely . Failure to do so could lead to loss of tire pressure during this process .
3 . When the universal adapter is firmly in place, press the locking lever down (see
Figure 4) .
4 . Turn the pressure selector dial until desired pressure is reached (see Figure 5) .
5 . Press power button (see Figure 6) . Unit will turn off automatically when set
pressure is reached .
6 . Raise the universal adapter's locking lever and remove from valve stem .

Maintenance

1 . This product has no user serviceable parts and does not require lubrication .
2 . Do not store outdoors . When not in use, store in a cool dry place .

InstRuCtIons FoR RePlACIng Fuse

1 . Shut off power to the unit .
2 . Use a flathead screwdriver to turn fuse cap counterclockwise .
3 . Replace old fuse with a 4A, 125V glass fuse .
4 . Reinsert fuse cap so that the word PUSH is on top and the image (
bottom .
5 . Use a flathead screwdriver to turn fuse cap clockwise .

teChnICAl seRVICe

For information regarding the operation or repair of this product, please call
1-800-543-6400 .
6
www.chpower.com
Unlocked
Valve
Stem
Figure 4 - lock universal Adapter securely
Figure 5 - Pressure selector Dial
Actual
Pressure
Figure 6 - Digital Pressure gauge and
Power Button
) is on the
Figure 7 - Replace Fuse
Universal
Adapter
Locked
Metal
Inflation
Needle
Desired
Pressure
Power
Button
Fuse
Fuse Cap

Publicidad

Tabla de contenido
loading

Tabla de contenido