Maintenance
INTAKE AIR FILTER
Figure 8

END OF OPERATION/STORAGE

1. Turn Auto On/Off switch (
2. Unplug power cord from wall outlet and wrap around handle to prevent damage when not in use.
3. Wearing safety glasses drain tank of air by pulling the ring on the safety valve. Use other hand to deflect fast
moving air from being directed toward your face.
4. Drain tank of condensation by opening drain valve on bottom of tank. Tank pressure should be below 40-50
psi when draining tank.
5. Air hose should be disconnected from compressor and open end hanging down to drain condensation.
6. Compressor and hose should be stored in a cool, dry place.

TECHNICAL SERVICE

For information regarding the operation or repair of this product, please call 1-800-543-6400.
OPERATION
CHECK OIL LEVEL
DRAIN TANK
CHECK AIR FILTER
CHECK SAFETY VALVE
CLEAN UNIT
CHANGE OIL
The intake filter element should be removed and checked periodically.
Filter
A clogged intake filter can decrease compressor performance and
Element
Filter
cause the compressor to overheat.
Cover
1. Rotate the fi lter cover counter-clockwise and remove.
2. Remove the fi lter element and inspect.
3. If the fi lter element is dirty or clogged, replace it.
4. Reinstall fi lter and cover.
) to OFF position (

MAINTENANCE SCHEDULE

DAILY
).
WEEKLY
MONTHLY