- Press the key during the 4ht lamp and release it as soon as the LED switches off.
It will then flash twice more to indicate that the lock status has been disabled, if this does not occur, repeat
the operation from scratch.
SETTING THE TIMER (only for special version)
In order to set the timer, the timer function must be enabled (jumper on 3, see Fig. 9).
If you do not wish to enable the relay, temporarily remove the channel selection jumper.
- Press and keep key 1 on the transmitter pressed (if previously authorized), then within
3 sec. you have to:
!
- Press and keep the key on the receiver pressed
- Release the transmitter key;
- Release the receiver key after a period equal to the time you wish to set (max. 2h 30 min.).
The time is now stored and will remain valid until it is reset.
NB: While setting the time on the timer, normal operation of the receiver is disabled (channels disabled).
- 40 -
TECHNICAL SPECIFICATIONS
RECEIVERS;
RECEPTION FREQUENCY
INTERMEDIATE FREQUENCY
INPUT IMPEDANCE
SENSITIVITY
POWER SUPPLY
STANDBY ABSORPTION
ABSORPTION OF 1st ENABLED CHANNEL
DECODING
N° OF CHANNELS
RELAY CONTACT
ENABLING TIME
DISABLING TIME
OPERATING TEMP.
DIMENSIONS
WEIGHT
30.875 - 40.685 MHz quartz controlled
455 kHz single conversion
52 Ohms
over 0.3 µV for successful signal (average
range 300 m. with ABK - ABKIT antenna)
10 V to 28 V DC or AC
15 mA
35 mA
30 bit digital (1.048.512 combinations)
1 or 2 depending on version
Normally open, max. 0.5A 125 Vac
Reception of 3 full codes (250 mS)
300 mS after last valid code
-10°C to + 55°C
67 x 34 17 h mm. BXIK - BXIK2
98 x 41 25 h mm. BX1K - BX2K
105 x 68 32 h mm. BXB2K - BB2BK
27 g. BXIK - BXI2K
62 g. BX1K - BX2K- 85 g. BXB2K - BB2BK
- 41 -
GB