Cleaning and routine maintenance & Alarm function
Empty the water container
1.Hold and pull out the water container
with two hands.
2.Tilt the water container, pour out the
condensed water.
3.Insert the water container.
!
WARNING:
1.Empty the water container after each use, the programme will be
paused and the "
the drying process. After the container emptyed, the dryer can be restarted
by pushing
2.Do not drink the condensed water.

Alarm function

Alarm Problem
"
"Is flashing
"
"Is flashing
"
E30
"
"
E32
"
"
E33
"
"
E34
"
" icon will flash if the water container is full during
Start/Pause
Alarm Reason
Water tank full or pump
error
Air flow block
Heater problem
Humidity sensor error
Temperature sensor error
button.
Buzzer Alarm
The Error Code is
flashing on X:XX
at Flash Rate 1 .
Meanwhile the
beep is sounded
every 15 minutes.
16
Release
Check the water tank and pump.
Check the filter and the air folw
Check the heater and the thermostat
Check the Humidity sensor and PCB
Check the front temperature sensor
Check the rear temprature sensor