Electric Connections - SEA 23001210/15 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
2 3 4 5 6 7 8 9 10 11
1
CN2
2
1
3
Flashing lamp
with flashing card
Opening
motor
Capacitor
Note1: When not used, bridge the N.C. contacts of safety in opening and/or of the photocell.
Note2: Output 24V, max 200mA.
Note3: When using the open collector output to manage an electro-lock, it must be powered by the
special relay card .
Security management: If the security opening command is busy during opening the gate recloses
immediately. The command is not active in closing
when the safety command (in closing) is busy during closing, the gate reopens. The command is not active
in opening.
If the two safeties are both active, the gate will not move and a start command will start it again. The gate will
restart in the opposite direction to the last engaged safety.
Attention: The motor comes without anti-squeezing security
device, it is necessary to use photocells and security edges.
2
Cod. 67410712
®

ELECTRIC CONNECTIONS

CN3
3
4
5
5
Common
motor
Closing
motor
Capacitor
English
12 13 14
CN E
1
2
3
4
+
GND
Data
Brown
Green
White
Rev. 00 - 03/2012
Note:
The open collector pilotes a relay
commanding a courtesy light.
+
GND
CN 1
1
2
N
F
POWER SUPPLY
230V
With inserted Jumper the encoder is
activated
JP1

Publicidad

Tabla de contenido
loading

Tabla de contenido