Items Supplied; Technical Data - Hilti PS 30 Manual De Instrucciones

Ocultar thumbs Ver también para PS 30:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
2.7 Warnings and error symbols in the display
Error message
Temperature warning
en
Electromagnetic interference
Calibration warning
2.8 Battery condition indicator
Number of segments shown
3
2
1
0
Battery symbol blinks

2.9 Items supplied

1
Tool
1
Hand strap
1
Soft pouch
1
Operating instructions
1
Manufacturer's certificate
4
Batteries
2
Markers

3 Technical data

Right of technical changes reserved.
NOTE
All values apply to individual rod-like metal objects positioned at right angles to the direction of movement of the
detector and when the surface of the concrete is flat and smooth with no external interference factors. Detection range
and accuracy is reduced when measurements are taken on brickwork.
PS 30
Detection range for locating ferrous metals
Detection range for locating non-ferrous metals (copper
and aluminium pipes)
12
Contact Hilti service
Inadmissible operating range
Too much interference from the surroundings
Calibration is required
> ∅ 8 mm (≧ # 3): 5...120 mm (¼ in ... 4¾ in)
∅ 6...8 mm: 5...100 mm (¼ in ...4 in)
Diameter at least 10 mm (½ in), Pipe wall thickness at
least 2 mm (³/₃₂ in): 5...80 mm (¼ in ... 3¹/₈ in)
Charge status in %
= 100 % capacity
= 80 % capacity
= 50 % capacity
= 20 % capacity
= fully discharged

Publicidad

Tabla de contenido
loading

Tabla de contenido