Sony DXC-390 Manual De Instrucciones página 28

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Adjusting and Setting with Menus
Setting item
Contents of setting
(VBS lock)
Adjusts the horizontal phase and
H. PHASE*
SC (subcarrier) phase during
SC. PHASE ROUGH*
external synchronization (with
SC. PHASE FINE*
VBS signal input).
(HD/VD lock)
Adjusts the horizontal phase
H. PHASE*
during external synchronization
(with HD/VD signal input).
* Displayed only when an external sync signal is input.
BAUD RATE
Switches the baud rate of the REMOTE
rear panel.
Sets to any of 19200, 9600, 4800, 2400 and 1200.
Normally, set to 9600 when the RM-C950 remote control
unit is connected to the REMOTE
Note
When the CMA-D3/C3CE is connected to the camera using
the CCMC-3MZ connecting cable, "CMA-D3" will appear
and you cannot select the baud rate.
28
(GB)
Chapter 2 Operation
D-SUB VIDEO
Ref. page
Switches the video signal output from the
29
connector (D-sub 9-pin) at the rear panel.
29
When the CMA-D3/C3CE is connected to the camera with
the CCMC-3MZ connecting cable, the item does not
connector at the
function.
D-SUB SYNC
Switches the sync signal output from the
connector.
connector (D-sub 9-pin) at the rear panel.
When the CMA-D3/C3CE is connected to the camera with
the CCMC-3MZ connecting cable, this item is fixed to
WEN.
Selection
Function
Outputs VBS signal.
VBS
Outputs Y/C signal.
Y/C
Note
Selection
Function
Outputs the composite sync signal.
C.SYNC
Outputs the WEN signal. When connecting peripheral
WEN
equipment, the signal is used as trigger pulse output to
the equipment.
Select the polarity of the WEN signal with the
POLARITY setting.
: Negative
: Positive
Note
RGB/SYNC
RGB/SYNC

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dxc-390p

Tabla de contenido