2. Remove the 2 screws (A) and the dethatcher cover
(B). Push the dethatcher equipment (C) up and out
to remove it.
A
B
C
Battery
LED on the battery
The green LED is flash-
ing
The error LED flashes
The error LED is on
937 - 006 -

Troubleshooting

Possible faults
The battery voltage is low
The battery is weak
The temperature in the work environ-
ment is too high or too low
Overvoltage
Cell difference too much (1V)
3. Push the new dethatcher equipment (C) into the
groove and down the hole. Attach the dethatcher
cover (B) and the 2 screws (A)
A
B
C
Possible procedure
Charge the battery. See
page 16 .
Charge the battery. See
page 16 .
Use the battery in temperatures between -10°C
and 40°C.
Check that the mains voltage is the same as on
the rating plate on the product.
Remove the battery from the battery charger. Wait
5 seconds and try again to charge the battery. If
the problem continues, speak to an authorised
service agent.
Speak to an approved service agent.