Maintenance schedule
Item
Checkpoint
Check for dust
Inspection of micro
levels between filter
filters
sock platform and
secondary filter.
Primary filter socks
Secondary filter
TROUBLE SHOOTING
Steps
Check for small holes or
perforations in the primary filter.
Repair with silicone sealant after
cleaning with compressed air or
vaccum. Check assembly of
primary filter seal.
Regular replacement
Secondary filter may be washed
with water. Ensure the filter is dry
prior to re-installation. On re-
installation ensure seal is firmly
pressed against the steel vaccum
motor mouning plate.
Frequency
Daily
Do this every six
months.
Replacement every
12 month.
– 15