Machine' ' ' ' s safety equipment
This section describes the machine's safety equipment, its
purpose, and how checks and maintenance should be carried
out to ensure that it operates correctly. See the "What is
what?" section to locate where this equipment is positioned
on your machine.
WARNING! Never use a machine that has
!
faulty safety equipment!
IMPORTANT! All servicing and repair work on the machine
requires special training. This is especially true of the
machine's safety equipment. If your machine fails any of the
checks described below you must contact your service
agent. When you buy any of our products we guarantee the
availability of professional repairs and service. If the retailer
who sells your machine is not a servicing dealer, ask him for
the address of your nearest service agent.
Switch
The power switch should be used to start and stop the
machine.
Checking the power switch
•
Start the machine by switching on the on-off switch.
•
Switch the on-off switch off to stop the machine.
•
A defective power switch should be replaced by an
authorized service workshop.
SAFETY INSTRUCTIONS
Ground fault circuit interrupter
Ground fault circuit interrupters are for protection in case an
electrical fault should occur.
The LED indicates that the ground fault circuit interrupter is on
and that the machine can be switched on. If the LED is not
on, push the RESET button (green).
Check the ground fault circuit interrupter
•
Connect the machine to the socket. Push the RESET
button (green) and the red LED lights up.
•
Start the machine by pressing the power switch.
•
Push the TEST button (blue).
•
The ground fault circuit interrupter should trip and the
machine switch off instantly. If not, contact your dealer.
•
Reset with the RESET button (green).
– 9
English