To use your stove with natural gas you should contact Whirlpool Service to change the nozzle and make the necessary
adjustments. See the "Service" section in page 34.
The qualified technician should make the conversion on the nozzles of each cooktop burner; the technician must test the
connection and the gas pressure in the oven, the values should be like the following:
NOTE: The gas type used for this range is LP. If you wish to use Natural gas with this range you will need a conversion kit
according to the following table. This kit can be ordered from the Authorized Whirlpool Solution Center. If you don't follow
theses indications your stove will generate soot and will require cleaning service which is not covered by the warranty of this
product.

Connect the Gas Supply Line

Depending of model a combination of fittings and pipes must be used to connect the stove to the existing gas supply line.
Your connection may be different than the diagram below, according to the supply line type, size, location and Range model.
To connect your stove use the material specified on the diagram below.
1.
2. Once you have connected the stove to the gas supply line, TURN ON the shutoff valve
and test all connections by brushing on an approved noncorrosive leak-detection
solution. Bubbles will show a leak. Correct any leak found.
3. Check the cooper piping for kinks or other damage so the gas flows freely throw the
pipe.
DON'T USE A LIGHTER TO LOOK FOR GAS LEAKS.
DON'T USE PLASTIC HOSES FOR THE CONNECTION TO THE SUPPLY LINE, EVEN THE
FLEXIBLE METAL TUBING, LEAKS MAY OCCUR.
In case of Range Model with full oven control follow instructions
:
1. Apply pipe-joint compound made for use with LP gas to the smaller thread ends of the flexible connector adapters
(see B and F in the following illustration).
09-May-2014 18:21:12 EDT | RELEASED
OPERATING LP GAS PRESSURE
2.75 kPa; 2750 Pa; 27.5 mbar; 28 cm WATER COLUMN
OPERATING NATURAL GAS PRESSURE
1.76 kPa; 1760 Pa; 17.6 mbar; 18 cm WATER COLUMN
Model
LWF7200
LWF7230
LWF7550
LWF7551
Outlet 5/8" Flared
In some European factories the letter "W" of the part code mentioned herein will be automatically
Conversion kit LP gas – Natural gas
W10665114
W10693387
W10665116
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")