User Functions
First disarm the system then enter Options, User Functions, then Master Code. This command is used to gain
access to the following list of master functions of the system:
Time and Date
Enter desired time and date.
Auto-Arm Time
The system can be programmed to arm at a programmed time each day, per partition. Upon entry of this section,
enter the desired Auto-Arm time for each day of the week.
At the selected Auto-Arm time, the keypad buzzers will sound for a programmed amount of time (programmable
by the installer only) to warn that an auto-arm is in progress. The bell can also be programmed to squawk once
every 10 seconds during this warning period. When the warning period is complete, the system will arm with no
exit delay and in Away mode.
Auto-Arming can be canceled or postponed by entering a valid access code only during the programmed warning
period. Auto-Arming will be attempted at the same time the next day. When the Auto-Arming process is canceled
or postponed, the Auto-arm Cancelation Reporting Code will be transmitted (if programmed).
If arming is inhibited by one of the following, the Auto-Arm Cancelation transmission will be communicated:
AC / DC Inhibit Arm
l
Latching System Tampers
l
Zone Expander Supervisory Fault
l
Note: For UL/ULC listed installations, the auto-arm feature shall be canceled when there are zones in an off-nor-
mal condition.
Enable DLS/Allow System Service
If enabled, the installer will be able to access Installer Programming via remote (DLS). The DLS window will
remain open for 6 hrs, during which time the installer will be able to enter DLS an unlimited number of times.
After the 6-hr window has expired, Installer's Programming will be unavailable again until the window is re-
opened.
Event Buffer
Displays the date, time and the full description of the event
l
The Log is organized from the most recent event (Top) to past events (Down)
l
The Left arrow scrolls forward in time
l
The Right arrow scrolls back in time
l
The Back returns you to the Home screen
l
This screen will time out to the Home screen after 30 seconds of inactivity
l
System Test
The system's bell output, keypad lights and communicator are tested. This test will also measure the panel's
standby battery.
Important:
To ensure that your system continues to function as intended, you must test your system weekly.
l
For UL HOME HEALTH CARE listed applications, the system shall also be tested weekly without AC
l
power. To remove AC from the control unit, remove the screw from the restraining tab of the plug in
adapter and remove the adapter from the AC outlet. After completing the test of the unit using only the
battery backup source, reconnect the plug in adapter and attach the screw through the restraining tab, so
that the adapter is securely attached to the outlet.
Should your system fail to function properly, contact your installation company immediately.
l
- 20 -