Technical Specifications - Festo HMPL Serie Instrucciones De Utilizacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
HMPL-...
13

Technical specifications

Type
Mounting position
Design
Medium
at speeds above 1 m/s
Operating pressure range
Connecting thread
Permitted temperature range 0 ° C ... max. + 60 ° C
Theoretical effective power
at 6 bar
Theoretical air consumption
at 6 bar (per 10 mm stroke)
Normal leakage
Repetition accuracy
End position cushioning
Cushioning length
Max. additional mass
– Horizontal fitting position
– Vertical fitting position
The permitted longitudinal
**)
force F
L
36
HMPL-...
12-...
As desired
Double-acting pneumatic cylinder with rod guiding bush
Filtered compressed air, lubricated or non-lubricated
(filter fineness 40 m m)
Use lubricated compressed air at all costs
At least 4 ... max. 8 bar
M5
– extending
51 N
– retracting
68 N
– extending
0.007 NL
– retracting
0.008 NL
Less than 2 Nl/h (when new, measured at 6 bar)
*
)
<
0.02 mm
Hydraulic cushioning
7.5 mm
2 kg
1 k
g
(vertical fitting)
25 N
16-...
20-...
104 N
158 N
121 N
188 N
0.012 NL
0.018 NL
0.014 NL
0.022 NL
9.5 mm
13.5 mm
5 kg
10 kg
2.5 kg
5 kg
40 N
75 N
Festo HMPL-... 0005NH – English

Publicidad

Tabla de contenido
loading