Electrical Specifications - Klein Tools MM2300 Manual De Uso

Ocultar thumbs Ver también para MM2300:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
Capacitance Features:
Safely discharge capacitor before
measurement.
• Reading may take up to 60 seconds
for large capacitors.
6.
Low Impedance (Low Z): < 600V
DO NOT use (LOW Z) mode at voltages greater than 600V.
• Press SELECT to choose AC or DC Voltage.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages
• See AC/DC Voltage instruction
7.
Frequency (Hz) / Duty Cycle: <500kHz
Features:
8.
Temperature:
Features:
Do Not apply voltage to thermocouple.
• Fahrenheit range: -58° to 1832°F (Celsius range: -50° to 1000° C)
Testing Fuse:
• When selecting uA or mA/A functions the meter will indicate
"LEAd" if the test leads are not properly connected to the meter.
• Note: This message remaining on the screen after properly
connecting the test leads is an indication that the fuse is open.
DC Voltage Measurement
Range
600mV
600V
˜
1000V
Overload Protection:
Input Impedance (Low
AC Voltage Measurement
Range
600mV
6V ~ 600V
1000V
continued on next page.
HOLD
HOLD
AUTO HOLD MAX/MIN
HOLD

ELECTRICAL SPECIFICATIONS

Resolution
0.1mV
0.1V
˜
1V
1000V
Z): 3kΩ, <200pF, up to 600V RMS
Resolution
0.1mV
1mV ~ 0.1V
1V
REL
Accuracy
± (0.5% + 4 digits)
± (0.8% + 10 digits)
Input Impedance
(Nominal): 10MΩ, <100pF
Accuracy
40Hz ~ 400Hz
± (0.75% + 5 digits)
± (0.75% + 8 digits)
Accuracy
400Hz ~ 5kHz
± (2.0% +3 digits)
± (2.0% +3 digits)
± (2.0% +3 digits)*

Publicidad

Tabla de contenido
loading

Tabla de contenido