In addition to the warranty, D
WALT tools are covered by our:
E
1 YEAR FREE SERVICE
D
WALT will maintain the tool and replace worn parts caused by
E
normal use, for free, any time during the first year after purchase.
90 DAY MONEY BACK GUARANTEE
If you are not completely satisfied with the performance of your
D
WALT Power Tool, Laser, or Nailer for any reason, you can return
E
it within 90 days from the date of purchase with a receipt for a full
refund – no questions asked.
LATIN AMERICA: This warranty does not apply to products sold
in Latin America. For products sold in Latin America, see country
specific warranty information contained either in the packaging, call
the local company or see website for warranty information.
FREE WARNING LABEL REPLACEMENT: If your warning labels
become illegible or are missing, call 1-800-4-D
replacement.
Troubleshooting
PROBLEM
SOLUTION
Motor does not run
Check power cord, plugs and outlet.
Ensure the on/off /tool control switch is in
the ON position ( ).
Suction capacity
Remove blockages in the suction nozzle,
decreases
suction tube, suction hose or filters.
Replace the paper or fleece bag.
Check for proper installation of the filters.
Clean or replace the filters.
Empty canister, refer to Empty Canister
under Operation.
PROBLEM
Vacuum stops running Thermal overload has been tripped:
Dust comes out while
vacuuming
WALT for a free
E
Automatic filter
cleaning is not
working
Power tool does not
turn on.
Volts
Hertz
Rated Current
Maximum speed current
Minimum speed current
Capacity
Weight
10
SOLUTION
1. Turn the vacuum off and disconnect
vacuum cleaner from power source.
2. Empty the canister, if needed.
3. Allow the unit to cool.
4. Plug
the
power
cord
appropriate outlet and turn on/off/tool
control switch to the ON position ( )
to test. If vacuum will not restart call
1-800-4-D
WALT (1-800-433-9258).
E
Check for proper installation of the filters.
Ensure filters are not damaged; replace if
necessary.
Ensure filter seals are in place and are
secure.
Listen for the solenoid clicking to ensure
the filter cleaning mechanism is working.
Ensure the on/off/tool control switch is in
the ACTIVATION position
.
SPECIFICATIONS
DWV012
120 V ~
60
15 A per UL1017
11.6 A
7 A
10 gallon (38 liters)
33.5 lbs. (15.1 kg)
into
an