These heavy-duty vacuums are for professional use. DO NOT let
children come into contact with the tool. Supervision is required
when inexperienced operators use this tool.
NOTE: This vacuum is intended for commercial use.
ASSEMBLY (FIG. 1–4)
WARNING: To reduce the risk of serious personal injury,
turn tool off and disconnect tool from power source before
making any adjustments or removing/installing attachments
or accessories. An accidental start-up can cause injury.
WARNING: When using electric appliances, always follow basic
safety precautions to reduce the risk of fire, electric shock and
personal injury.
WARNING: The filters (I) must always
be in place while vacuuming, except
as described under Wet Pick Up
Applications
under
Operation.
When vacuuming fine dust, you may
also use an additional paper bag or
fleece bag to make emptying the
canister easier.
1. If optional paper or fleece bag (R) is to be used, install as shown
in Figure 3.
NOTE: Be careful not to tear the bag. Place bag securely onto
inlet (J) to provide a tight seal for maximum dust collection
performance.
FIG. 3
R
J
FIG. 2
I
FIG. 4
J
G
5
2. Place the vacuum head (C) onto the canister and secure it by
closing the canister latches (D).
3. Insert end of hose (G) into twist-lock hose inlet (J) and rotate
counterclockwise to lock in place.
OPERATION
1. Plug the power cord into an appropriate outlet.
2. Turn the on/off/tool control
switch (O) to the ON
position ( ).
3. Set the variable suction dial
(N) to the desired position.
This feature allows the user
to control the vacuum's
power, suction and noise.
NOTE: This setting also controls the level of suction. This is very
useful in applications where the vacuum creates unacceptable
levels of drag to the work piece.
4. Follow the direction under Connecting to Power Tools to
connect to the power tool to be used.
CONNECTING TO POWER TOOLS (FIG. 1, 6)
1. Plug the vacuum power cord into an appropriate outlet.
2. Plug the power tool into the outlet (M).
3. Turn on/off/tool control switch (O) to the ACTIVATION position
. This allows the vacuum to be turned on and off
automatically with the power tool.
NOTE: The vacuum cleaner starts automatically within
0.5 seconds and continues to run for 15 seconds after the
power tool has been turned off.
4. To switch back to manual mode, turn the on/off/tool control
switch (O) to the ON position ( ). In manual mode the tool and
the vacuum are turned on and off independent of each other.
FIG. 5
N
O