Settings From The Mode Button - Sime HOME Manual De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

System inertia
this is a parameter which adjusts the reaction time of the ad-
justment algorithm, to be associated with inertia or with the
size and type of building and the heating system.
flow temp. min. set
it is the lower limit of the calculated flow temperature (use-
ful in the case of low efficiency systems with low calculated
temperatures)
antifreeze enable
: enable the antifreeze protection program
yes setting
no setting: the heating will remain off when in the function
mode oFF, suMMeR and in periods of Reduced mode auto if
the room sensor is disabled.
antifreeze set
this is the room temperature (antifreeze) below which the de-
vice makes a heating request at the minimum flow set. the
request remains active until the room temperature has ex-
ceeded the "antifreeze temperature + 0.6°c"
room probe offset
this is the value used to correct the room temperature read-
ing by the sensor inside the device.
40
4.3

Settings from the mODE button

From the "main screen"
Zone 1
Winter manual - set 20.0°C
Menu
– press the button
mode
one of the three Modes will be highlighted
"function mode"
(eg. "Winter")
Summer
Esc
– press the encoder
to confirm the highlighted "mode"
click
and go into the "rows"
Hot water
Heating
Holiday function
Esc
– Rotate the encoder
to select "heating"
EN
Th 20 Mar 2014
10:30
Mode
to go into the screen to select
Off
Winter
Back
Winter
MAN 40°C
MAN 20.0°C
OFF
Back

Publicidad

Tabla de contenido
loading

Tabla de contenido