Oil capacity to the correct level according to the model is:
 Models 2000 to 3000W
 Models 4000 to 7000W
OIL FILLING HOLE
7 Install the oil filling plug again
IMPORTANT: In order to comply with environmental requirements, the used oil
must be placed in a sealed container and taken to the service station for
recycling. Do not discard the trash and do not spill on the floor.

8.2 Air filter maintenance.

NOTE: A dirty air filter will restrict the air flow in the carburetor, which will
cause incorrect combustion resulting in serious problems for the engine. Clean
the filter regularly according to the maintenance plan in this manual and with
more frequency in dusty areas.
NOTE: Never operate the generator without the air filter, otherwise this will
cause a fast engine abrasion.
WARNING: Do not use gasoline or solvents for low ignition point when
cleaning the filter. They are flammable and explosive under certain conditions.
0.6 liters.
1.1 liters.
MAXIMUM LEVEL
OIL FILLING CAP
26