Model
Regulation – Voltage – Frequency
Maximum AC
400V 0.8
Nominal AC
400V 0.8
Maximum AC
230V
Nominal AC
230V
Engine model
Cubic capacity
Engine type
Sound level to 7m
Max. pressure guaranteed CE-LwA pursuant to
2000/14/EC
Startup type
Fuel tank capacity
Hourly consumption - Autonomy at 25% 50% 75% loads
Oil capacity – Type of oil
Transportation kit
Dimensions without / with wheels L x W x H (cm)
Machine weight / gross packaging (Kg)
Reference
Noise level measurements:
 The noise level at 7 m is the average sound level (lpA) obtained in four
directions and 7 meters from the generator.
NOTE: The noise level may vary noticeably in different environments.
Equipment regulation compliance:
 Tested in accordance to EN12601:2010: safety in generators powered by
combustion engine
 In accordance to guidelines 2006/42/EC Machinery safety
 In accordance to guidelines 2006/95EC
 In accordance to guidelines 2004/108/EC Electromagnetic compatibility
 In accordance to 2000/14/EC (guideline 2005/88/EC) Sound emissions of the
exterior equipment on stage II June 2006.
RENT AM-7T
Electronic stabilizer – 230/400V – 50Hz
6000w (7500va)
5500w (6800va)
4400w
4000w
Make GENERGY model SG150E
420cc
4-stroke OHV, air forced cooling.
74dB (A)
97dB
Manual
6.5L
(1.5 l/h -4.3h) (1.8 l/h – 3.6h) (2.4 l/h – 2.7h)
1.1L SAE10W30 - SAE10W40
Yes, with 10" rubber tires and metallic wheel.
74 x 53 x 58 / 77 x 69 x 60
81 / 90
2013037

Low voltage

37