Adjusting Air Pressure - Metabo HPT NV 83A2 Instrucciones Y Manual De Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
(1) DISCONNECT AIR HOSE FROM NAILER.
REMOVE ALL NAILS FROM NAILER.
□ ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
□ THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY.
Push Lever
(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
Connect the air hose.
Do not load any nails in the Nailer.
□ THE NAILER MUST NOT LEAK AIR.
Hold the Nailer downward and pull the trigger.
□ THE NAILER MUST NOT OPERATE.
14
Trigger
Do not connect
air hose
Pull Trigger
(3) With fi nger off the trigger, depress the push lever
against the workpiece.
□ THE NAILER MUST NOT OPERATE.
Depress Push Lever
(4) Without touching the trigger, depress the push lever
against the workpiece.
Pull the trigger.
□ THE NAILER MUST OPERATE.
(5) With the Nailer off the workpiece, pull the trigger.
Depress the push lever against the workpiece.
□ THE NAILER MUST OPERATE.
(6) If no abnormal operation is observed, you may load
nails in the Nailer.
Drive nails into the workpiece that is the same type to
be used in the actual application.
).
□ THE NAILER MUST OPERATE PROPERLY.
2

ADJUSTING AIR PRESSURE

Adjust the air pressure at recommended operating
pressure 70 – 120 psi (4.9 – 8.3 bar 5 – 8.5 kgf/cm
according to the length of nails and the hardness of
workpiece.
The correct air pressure is the lowest pressure which will
do the job. Using the Nailer at a higher than required air
pressure unnecessarily over stresses the Nailer.
Do not pull Trigger
WARNING
● Do not exceed
120 psi (8.3 bars
8.5 kgf/cm
).
2
)
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Nv 65acNv 50a1

Tabla de contenido