Stopping The Generator; Display Messages - Dometic TEC30EV Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
TEC30EV
8.5

Stopping the generator

➤ Stop the generator with the on/off switch (fig. 3 2, page 4).
If the generator does not stop: switch it off with the main switch (fig. 2 1,
page 4).
Stopping the generator for a prolonged time
➤ Switch it off with the main switch (fig. 2 1, page 4).
➤ Disconnect the battery.
8.6

Display messages

Display message
Description
LOW BATTERY
The battery voltage has fallen
below the minimum value for
starting up (9V).
OIL CHANGE
The number of prescribed
operating hours has been
reached for changing the
engine oil.
NO FUEL
The fuel in the tank is in
reserve.
CHECK OIL LEVEL
Insufficient engine oil.
OIL TEMP PRESS
Insufficient engine oil.
EN
Generator behaviour
The generator does not start. Charge the battery.
The generator continues to
run.
The generator continues to
run.
The generator stops.
The generator stops.
Operating the generator
Measures
Change the oil (see chapter
"Changing the oil" on
page 24), then restart the
generator by pressing and
holding down the start but-
ton.
Refuel.
Fill up with oil (see chapter
"Checking the oil level" on
page 21).
Fill up with oil (see chapter
"Checking the oil level" on
page 21).
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

9102900033Tec 30d ev

Tabla de contenido