Parameter
number Description
P19
Operating logic of the FOTO input
P20
Selects the operation of the second
button on the remote control
P21
Channel 2 output activation time
P22
Pedestrian opening distance
P23
Type of encoder
P24
Acceleration on starting
P25
Deceleration on slowing down
P26
Operation with limit switch
P27
Flashing light active also when run-
ning only on battery
P28
Operation with battery
P29
Manned, AP/CH controls opening
by keeping the button pressed, PED
controls closing by keeping the button
pressed
P30
-
P31
Selecting the direction of opening
the gate/barrier
N.B.: After calibrating the travel, if parameters 11-12-13-14 and 31 are changed after confirming with the ENTER key the display reads APCH, you must
give the command by pressing the APCH button, the gate/barrier will perform a complete opening and closing cycle (with this operation, the control unit
saves the new current thresholds with the modified speeds)
8.5 DEF:
used to set the control panel on the default parameters, except for parameters: 9-10-11-12-13-14-15-22-23-24-26-31 press and release the OK
button, the display shows 4 dots to confirm the operation.
N.B. To set all the parameters to default: power up the control panel by holding down the ESC key for at least 10 seconds.
8.6 CNT:
used to view the number of openings followed by the gearmotor, the first counter A displays the number of absolute operations, the second
counter P displays the operations performed after a reset controlled by the installer. This is shown in the following example:
x6
Pressing the UP button 6 times displays CNT (counter)
Press the OK button, the display shows the letter A (absolute counter cannot be reset) the number that follows should be multiplied by 10000
Press the DOWN button, the display shows the number to be added to get the total openings performed by the motor: absolute number =
(000*10000)+(7000)= 7000
Press the DOWN button, the display shows the letter P (partial counter can be reset) the number that follows should be multiplied by 10000
Press the DOWN button, the display shows the number to be added to get the openings after resetting the partial counter: partial
number = (000*10000)+(1000)= 1000, this means that it was reset on 6000 openings. To reset the partial counter, press
and hold down the OK button for at least 5 seconds.
36
Settable values
1: the FOTO input tripping reverses the movement of the
gate/barrier during closing
2: the FOTO input tripping stops the movement of the gate/
barrier during opening and closing, when disengaged it goes
back to opening again
2CAN= activates the 2CH output
PEDO= controls pedestrian opening
1-60 seconds
50-250 cm
1- Magnetic encoder, 2- Optical encoder
1-5 ( 1=maximum acceleration 5= minimum acceleration)
1-8 ( 8= maximum deceleration 1= minimum deceleration)
OFF = no limit switch
OP = opening limit switch fitted
CL= closing limit switch fitted
OPCL= opening and closing limit switch fitted
ON/OFF
0: functionality does not change
1: after an apch command the gate/barrier opens and re-
mains open
2: the gate/barrier opens and remains open
0: function disabled
1: function active if the safety devices are open (FOTO and
STPA)
2: function active with apch and ped inputs, maintains auto-
matic operation if controlled remotely
-
OFF: opens to the left
ON: opens to the right
x5
EN
Default value
Modified value
1
0
1 second
148 cm
1
3
7
OFF
OFF
0
0
-
OFF