ENGLISH
TONOMETER
Icare® PRO (Model: TA03)
INSTRUCTION MANUAL
The information in this document is subject to
change without prior notice.
In a conflict situation the English version prevails.
0598
This device complies with:
Medical Device Directive 93/42/EEC
Canadian Medical Device Regulations
RoHS Directive 2011/65/EU
Copyright © 2017 Icare Finland Oy
Made in Finland
Icare Finland Oy
Äyritie 22, FI-01510 Vantaa, Finland
Tel. +358 9 8775 1150, Fax +358 9 728 6670
www.icaretonometer.com,
info@icarefinland.com
1. SAFETY INSTRUCTIONS
WARNING
The tonometer must not come into contact with
the patient's eyes, except for the probes, which
may do so for a fraction of a second during
measurement. Do not bring the tonometer
into contact with the eye or push it into the eye
(the tip of the probe should be 3–7 mm, or 1/8 –
9/32 of an inch, from the eye).
WARNING
To prevent contamination, avoid touching it
directly.
WARNING
Never spray, pour or spill liquid onto the Icare
tonometer, its accessories, connectors, switches
or openings in the chassis. Dry any liquid on the
surface of the tonometer immediately.
WARNING
Do not connect the USB cable during
measurement.
WARNING
Do not change the probe base when the USB
cable is connected.
WARNING
The probes are for single use only. Use probes
taken only from the original, intact packaging.
The manufacturer cannot guarantee the sterility
of the probe once the seal is compromised.
Re-sterilization or re-use of the probe could
result in incorrect measurement values or in
the breakdown of the probe and will void all of
Icare Finland Oy's responsibilities and liabilities
related to the safety and effectiveness of the
device.
WARNING
Do not touch the USB cable terminal and
patient simultaneously.
WARNING
When using a PC to charge your Icare PRO, keep
both the PC and Icare PRO 1.5m/5 ft. or more
from the patient.
WARNING
No modification of this equipment is permitted.
WARNING
The probe base, screws, collar and probes are
small enough to be swallowed by a child. Keep
the tonometer out of the reach of children.
WARNING
Use of this equipment adjacent to or stacked
with other equipment should be avoided
because it could result in improper operation. If
such use is necessary, this equipment and the
other equipment should be observed to verify
that they are operating normally.
WARNING
Use of accessories other than those
specified or provided by the manufacturer
of this equipment could result in increased
electromagnetic emissions or decreased
electromagnetic immunity of this equipment
and result in improper operation.
CAUTION
• When you have opened the package, check
for any external damage or flaws, particularly
for damage to the case. If you suspect that
there is something wrong with the tonometer,
contact the manufacturer or distributor.
English
1