ALARM REC MODE SET SETTING
4
Turn the shuttle dial clockwise, use the jog dial to set the
recording method (example: " FRAME" ), and then turn the
shuttle dial clockwise.
The cursor moves to AUDIO RECORDING.
Note:
•
When FRAME/FIELD RECORDING is selected, the recording
speed appears in REC CYCLE and the maximum number of
recordings appears after it in brackets.
=> (30721 ALARMS CAN BE RECORDED)
•
The field and frame recording speeds vary depending on the
PICTURE QUALITY setting. Refer to the Recording speed table for
details. (See page 11.)
5
Turn the shuttle dial clockwise, use the jog dial to set audio
recording (example: " ON" ), and then turn the shuttle dial.
The cursor moves to ALARM RECORDING.
Note:
•
Audio recording can be set when the REC CYCLE setting is 0.10
SEC (FIELD) or 0.20 SEC (FRAME) or more.
•
When set to "ON", the letter "A" (audio recording indicator) appears
in front of the REC CYCLE recording speed, and the maximum
number of recordings appears after it in brackets.
=> (25166 ALARMS CAN BE RECORDED)
6
Turn the shuttle dial clockwise, use the jog dial to set alarm
recording mode (example: " MODE1" ), and then turn the
shuttle dial.
The cursor moves to REC CYCLE.
Display example: Alarm recording settings
•
OFF: Alarm recording is not carried out.
•
MODE1: Alarm recording is always carried out regardless of
the timer recording settings.
•
MODE2: Alarm recording is only carried out when timer
recording is in progress.
•
MODE3: Alarm recording is only carried out when timer
recording is not in progress
•
MODE4: Alarm recording is carried out only during the times
set by the timer. This cannot be used for normal
recording.
Note: If alarm recording is set to a setting such as MODE1,
PRE-ALARM RECORDING setting will be enabled ("***" will
change to "OFF").
English
<ALARM REC MODE SET>
PICTURE QUALITY
: SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING
: OFF
ALARM RECORDING
: OFF
REC CYCLE : 0.20SEC.
DURATION: 1SEC
PRE-ALARM RECORDING
: ¤¤¤
<ALARM REC MODE SET>
PICTURE QUALITY
: SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING
: ON
ALARM RECORDING
: OFF
REC CYCLE : A0.20SEC.
DURATION: 1SEC
PRE-ALARM RECORDING
: ¤¤¤
REC CYCLE : ¤¤¤ SEC.
DURATION: ¤¤¤
7
Turn the shuttle dial clockwise, use the jog dial to set the
recording speed (example: " 0.13" ), and then turn the shuttle
dial.
DURATION of "1SEC" flashes.
Note: When the recording speed is selected, the maximum number of
recordings appears after it in brackets.
=> (17066 ALARMS CAN BE RECORDED)
8
Use the jog dial to set the recording time duration (example:
" 5" ), and then turn the shuttle dial.
The cursor moves to PRE-ALARM RECORDING.
9
Press the EXIT/OSD button.
The display returns to the normal screen.
Alarm settings appear in the operating display section. When an
alarm is triggered, the number of alarms is displayed.
EXIT/OSD
Note: If another alarm occurs while alarm recording is in progress,
alarm recording continues with images for the second alarm
being recorded from the point where the second alarm occurred.
If several alarms have occurred at the same time, they are
treated as a single alarm until the alarms stop.
55
<ALARM REC MODE SET>
PICTURE QUALITY
: SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING
: ON
ALARM RECORDING
: MODE1
REC CYCLE : A0.13SEC.
DURATION: 5SEC
PRE-ALARM RECORDING
: OFF
REC CYCLE : ¤¤¤ SEC.
DURATION: ¤¤¤
=> (03355 ALARMS CAN BE RECORDED)
ALARM TRIGGER
: ALARM
MOTION SENSOR
->
01-01-01 ALARM 0000
05:53:44 SF 0.13SEC