OPERATION
9. Slide pedal between two mounting arms on back
of machine. Align and insert clevis pin through
arms and slot in pedal, secure with cotter pin
(Figure 5).
FIG. 5
10. Attach squeegee assembly to bracket. Use (2)
thumb screws to secure (Figure 6).
FIG. 6
11. Connect 117 cm (46 in) vacuum hose to squeegee
assembly and to neck on machine lid (Figure 7).
FIG. 7
14
Home
Find... Go To..
MACHINE SETUP
1. Connect 15m (50 ft) power cord to machine pigtail
cord.
2. Plug power cord into a grounded outlet (Figure 8).
Grounded
3 Hole Outlet
Ground Pin
FIG. 8
FOR SAFETY: Do not operate machine with the
use of additional extension cords. Only use
manufacturer's extension cord equipped with
machine which has proper capacity and is
grounded.
WET VACUUMING
1. Open machine cover and remove vacuum bag
from recovery tank (Figure 9).
FIG. 9
2. Make sure automatic float shut-off screen is in
place (Figure 10).
FIG. 10
Typhoon 1610P/1612 (08- -07)