Thank you for buying this product, our company is sure that you will
be more than satisfied with the product's performance. The product
is supplied with a "Warnings" leaflet and an "Instruction booklet".
These should both be read carefully as they provide important
information about safety, installation, operation and maintenance.
This product complies with the recognised technical standards and
safety regulations. We declare that this product is in conformity
with the following European Directives: 89/336/EEC, 73/23/EEC,
98/37/EEC, 99/05/EEC (and subsequent amendments).

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
• The "Warnings" leaflet and "Instruction booklet" supplied with
this product should be read carefully as they provide important
information about safety, installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc)
according to the provisions set out by current standards. Keep
nylon or polystyrene bags out of children's reach.
• Keep the instructions together with the technical brochure for
future reference.
• This product was exclusively designed and manufactured for the
use specified in the present documentation. Any other use not
specified in this documentation could damage the product and
be dangerous.
The Company declines all responsibility for any consequences
resulting from improper use of the product, or use which is different
from that expected and specified in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with
the following European Directives: 89/336/CEE, 73/23/EEC,
98/37/EEC and subsequent amendments. As for all non EEC
countries, the abovementioned standards as well as the current
national standards should be respected in order to achieve a
good safety level.
• The Company declines all responsibility for any consequences
resulting from failure to observe Good Technical Practice when
constructing closing structures (door, gates etc.), as well as from
any deformationwhich might occur during use.
• The installation must comply with the provisions set out by the fol-
lowingEuropean Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC
and subsequent amendments.
• Disconnect the electrical power supply before carrying out any
work on the installation. Also disconnect any buffer batteries, if
fitted.
• Fit an omnipolar or magnetothermal switch on the mains power
supply, having a contact opening distance equal to or greater
than 3,5 mm.
• Check that a differential switch with a 0.03A threshold is fitted
just before the power supply mains.
• Check that earthing is carried out correctly: connect all metal
parts for closure (doors, gates etc.) and all system components
provided with an earth terminal.
• Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing,
conveying and shearing.
• Position at least one luminous signal indication device (blinker) where
it can be easily seen, and fix a Warning sign to the structure.
• The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components
are used.
• Only use original parts for any maintenance or repair opera-
tion.
• Do not modify the automation components, unless explicitly
authorised by the company.
• Instruct the product user about the control systems provided and
the manual opening operation in case of emergency.
• Do not allow persons or children to remain in the automation
operation area.
INSTALLATION MANUAL
• Keep radio control or other control devices out of children's reach,
in order to avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on
the automation system, and always request the assistance of
qualified personnel.
• Anything which is not expressly provided for in the present instruc-
tions, is not allowed.
• Installation must be carried out using the safety devices and
controls prescribed by the EN 12978 Standard.
• Fit any fixed control within sight of the door but away from moving
parts, higher than 1.5 m.
• Add a label bearing the following notices:
"Keep children away from the moving door".
"WARNING: risk of squashing".
Regularly check that the door reverses its movement when colliding
with an obstacle 50 mm away from the floor and, if necessary, set
it correctly.
2) GENERAL OUTLINE
The EOS 120 system is suitable for motorising sectional doors (fig.
3), protruding fully retracting spring-operated overhead doors (fig.
2) and counterweight overhead doors provided with an appropriate
towing arm (fig. 4). The overhead door must not be higher than 3
metres. Its easy installation allows fast fitting without needing the
door to be modified. The irreversible gearmotor keeps the door
locked in the closing position.

3) TECHNICAL SPECIFICATIONS

3.1) Actuator
Power supply:.....................230V~±10%, 50/60Hz single-phase (*)
Motor voltage:...........................................................................24V
Max. power absorbed from mains:.........................................236W
Lubrication:.........................................................permanent grease
Towing and pushing force:....................................................1200N
Working stroke:.......TRACK L.=2900 working stroke=2400 mm(**)
..............................TRACK L.=3500 working stroke=3000 mm(***)
Average speed:...................................................................5 m/min
Impact reaction:...............integrated torque limiter on control panel
Manoeuvres in 24 hours:...........................................................100
Limit switch:...........................................Electronic with ENCODER
Courtesy light:........................................24V~ 25W max, E14 bulb
Working temperature:...............................................-15°C / +60°C
Degree of protection:...............................................................IPX0
Motor head weight:....................................................................5kg
Noise level:.......................................................................<70dB(A)
Dimensions:.......................................................................see fig.1
(*) Available in all mains voltages.
(**)By turning the motor head by 90° (Fig.11) the useful stroke will be
2580 mm.
(***) By turning the motor head by 90° (Fig.11) the useful stroke will be
3180 mm.

4) ACTUATOR INSTALLATION

4.1) Preliminary checks

• Check that the door is balanced.
• Check that the door slides smoothly along its entire travel.
• If the door has not been newly installed, check the wear condition
of all its components.
• Repair or replace faulty or worn parts.
• The automation reliability and safety are directly influenced by
the state of the door structure.
• Before fitting the motor, remove any superfluous ropes or chains
and disable any unnecessary appliances.
4.2) FITTING
After unpacking, dispose of the parts which make up the package
properly, by separating the different type of materials (cardboard,
polystyrene, PVC, etc.) according to the national rules in force.
1) Remove the existing locking bolt from the cremone bolt of the door.
ENGLISH
~±10%, 50/60Hz single-phase (*)
±10%, 50/60Hz single-phase (*)
~ 25W max, E14 bulb
25W max, E14 bulb