Locating Malfunctions - ENAR QGH 25/45 Manual De Instrucciones

Reglas vibrantes fijas y extensibles
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CABLE SCHEME FOR THREE PHASE MOTOR CONNECTED AT 380 V (QP)
1- PLUG 3Ph+Earth (103727)
3- CABLE TO SWITCH SECTION 2,5 mm2
5- EARTH CABLE (green-yellow)
7- SWITCH (103718)
9- CABLE DE INTER. A MOTOR SECCION 2,5 mm2 10- CABLE DE INTER. A MOTOR SECCION 2,5 mm2
11- TERMINAL BOX
13.- SWITCH BOX (103739)
6

LOCATING MALFUNCTIONS

The motor doesn´t work
The screed doesn't vibrate
The electric motor is overheating
The vibrating consists of one set of beams of Aluminium or Steel (4 beams) with a length of 2,6m that
extend until 4,5m. To extend the beams, unscrew the tongs and pull them from both extremities.
It consists also of a frame (the vibrating group) that is coupled on the beams and tightened with 4 tongs.
Over the frame, the motor basis is mounted on 4 silent-blocks that insulate the motor from the vibrations,
supporting the motor types, electric and petrol types.
FIXED AND EXTENSIBLE VIBRATING SCREEDS
PROBLEM
2- CABLE TO SWITCH SECTION 2,5 mm2
4- CABLE TO SWITCH SECTION 2,5 mm2
6- EARTH CONNECTION POINT
8- CABLE FROM SWITCH TO MOTOR SECTION 2,5 mm2
12- MOTOR (104232)
CAUSES/SOLUTIONS
Check the gas level
Check the gas admission key is open.
Check the de choke position (gas).
Check the power source (electric).
Check the cables, the switch and the plug electric.
Check the oil level of the exciter
Check the ecciter's belt.
Clean the air ventilation (inlet and outlet).
Check the power supply type.
en
9
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Qg 25/45Qp 25/45Qpm 25/45

Tabla de contenido