Charge Acceptance Test; General; Preparations - Fronius Acctiva Professional Flash UCN US Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Charge acceptance test

General

Charge acceptance test mode is used to determine a battery's ability to accept a charge.
The charge acceptance test takes place as follows:
-
-
A prerequisite for a satisfactory charge acceptance test is compliance with EU standard
EN-50342-1:2006 item 5.4 (battery approx. 50% discharged).

Preparations

To ensure the battery is about 50% discharged, the following preparations can be carried
out immediately before the charge acceptance test:
1.
2.
3.
charge acceptance testing is conducted automatically within a few minutes; if the
result is positive, the device will then switch automatically to standard charging
mode and charge the battery
if the result is negative, „Test Fail" appears on the charger's screen and charging of
the battery is halted
Fully charge the battery
Calculate the discharge current
Battery capacity (Ah)
=
10
Charge battery for approx. 5 hours with the calculated discharge current
15