Troubleshooting
Troubleshooting
Charging terminals connected to wrong poles
Cause:
Remedy:
Charging terminals short-circuited
Cause:
Remedy:
Cause:
Remedy:
Over-temperature
Cause:
Remedy:
Cause:
Remedy:
Safety cut-out
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Fan blocked/faulty
Cause:
Remedy:
Cause:
Remedy:
Fuse faulty
Cause: Secondary fuse faulty
Remedy: Contact specialist dealer
Charging terminals connected to wrong poles
Swap charging terminals round
Short-circuit on the charging terminals
Rectify short-circuit on the charging terminals
Battery not detected
Check that charging terminals are properly connected, press Start/Stop
button for 5 seconds
Over-temperature - charger too hot
Allow charger to cool down
Air inlets and outlets covered
Ensure air inlets and outlets are not obstructed
Battery faulty
Check battery
Charger incorrectly set
Check settings: Ah, voltage
Incorrect battery type (e.g. NiCd), incorrect number of cells (voltage)
Check battery type
Fan blocked
Check air inlet, remove foreign bodies if necessary
Fan faulty
Contact specialist dealer