Descargar Imprimir esta página

Miele UG 6163 Instrucciones De Montaje página 24

Zócalo del lado descontaminado y contaminado

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
Produktgruppen 512, 592
24 von 26
am
Parts required
Quantity
Mat. no.
1
07493360
1
07493370
1
07493380
1
07493390
1
07493400
1
07493410
1
06585110
Note
This service and repair work should only be carried out by a suitably qualified electrician (with specialist training,
knowledge and experience, and recent related work experience) in accordance with all appropriate local and national
safety regulations.
Servicing, modification, testing and maintenance of electrical appliances should only be carried out in accordance
with all appropriate legal requirements, accident prevention regulations and valid standards. All regulations of the
appropriate utility supply companies and standards relating to safety (not limited to electrical safety) are to be complied
with.
Danger!
Even with the machine switched off, voltage may be applied to some components.
Before starting any service work, the machine must be disconnected from the power supply. Suitable measurements must
be made to ensure that this is the case.
A general visual check should always be carried out.
Incorrect conversion or service work could lead to a risk of fire.
Danger!
Risk of injury during installation:
Risk of electric shock. Before starting any service work, the machine must be disconnected from the power supply.
Installation can only be carried out with the washing machine or tumble dryer not installed. For deinstallation, see
the appropriate operating instructions.
Risk of crushing. Wear slip-proof working gloves and safety shoes.
Risk of crushing. When carrying out work, ensure that parts of the body, especially the hands and feet, are not
positioned under or between machines.
Risk of accident. Ensure that children or pets cannot access the work area while installation work is being carried
out.
Risk of injury, particularly to the back. The relation of the weight of the machine to the physical strength of the
technician must be taken into account. For machine weight details, see the operating instructions.
Risk of injury due to incorrect installation:
Always bolt the machine to the stand.
With floor mounting, secure all four brackets.
02.03.2012
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
Designation
Installation instructions - Stand UG 6163, octoblue, for PW 6163
Installation instructions - Stand UG 6163, stainless-steel, for PW 6163
Installation instructions - Stand UG 6243, octoblue, for PW 6243
Installation instructions - Stand UG 6243, stainless-steel, for PW 6243
Installation instructions - Stand UG 6323, octoblue, for PW 6323
Installation instructions - Stand UG 6323, stainless-steel, for PW 6323
Pipe HTEM DN 75 x 250 to extend floor drain outlet by at least 170 mm
M.-Nr. 07564361

Publicidad

loading

Este manual también es adecuado para:

Ug 6243Ug 6323