8.3.6
STOVE TURNED OFF
When the stove is turned off, the display shows the following
information (see drawing D26):
8.3.7
RE-IGNITION OF THE STOVE
When the stove is turned off it is not possible to restart it until a
safety time is passed and the stove is cold enough. If you try
to start-up the stove, all the leds will light up in red as shown in
drawing D27.
9
ALARMS
In case of an anomaly during operation, the electronics of the stove intervene and highlight the
irregularities that have taken place in the different ways of working, depending on the type of fault.
Every alarm situation makes the stove to be automatically blocked. By pressing the display button 3
seconds we can unblock it. Once the stove has reached the appropriate cooling temperature, the user
can restart it up.
9.1
POWER SUPPLY FAILURE (BLACK OUT)
In the event that power supply is cut for less than 30 seconds, the stove will restart and continue with
its normal working state.
In the event that power supply is cut for greater than 30 seconds, when power is restored, the stove,
as a safety measure, goes straight to the Final Cleaning stage until the stove temperature reaches
the appropriate cooling temperature. Once the final cleaning has finished, the display will show the
drawing D28, and you must reset the alarm pressing for 3 seconds the display button.
9.2
SMOKE TEMPERATURE PROBE ALARM
This alarm goes off when the probe in charge of detecting the exhaust smokes temperature is
disconnected or fails. During the alarm status, the stove will be in the turn-off stage (see drawing
D29). You must reset the alarm by pressing the display button for 3 seconds.
9.3
SMOKE TEMPERATURE EXCESS ALARM
It goes off when the probe detects a smoke temperature higher than 270°C. The display lights up as
shown in the drawing D30.
During the alarm state, the stove will be in the turn-off stage. You must reset the alarm by pressing the
display button for 3 seconds.
9.4
DAMAGED SMOKE EXTRACTION FAN ALARM
It goes off when the smoke extraction fan breaks down. If this happens, the stove stops and the display
will show the following alarm (see drawing D31). Right after, the turn-off stage will be immediately
activated.
To deactivate the alarm press button 3 and the stove will come to the normal state after doing the final
cleaning.
9.5
IGNITION FAILURE ALARM
In case of ignition failure (after 25 minutes at least) the display will show up an alarm as follows (see
drawing D32).
To deactivate the alarm press button 3 and the stove will come to the normal state after doing the final
cleaning.
9.6
SWITCHING-OFF FAILURE DURING WORKING PHASE
If the flame extinguishes during the working stage and the smoke temperature goes lower than the
minimum working threshold, the alarm goes off and the turn-off stage will be immediately activated (see
drawing 33).
To deactivate the alarm press button 3 and the stove will come to the normal state after doing the final
cleaning.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
Blue
D26
Red
22
Blue
D27
Red
D28
Blue
Red
Blue
D29
Red
Blue
D30
Red
Blue
D31
Red
Blue
D32
Red
Blue
D33
Red
MOD. BERTA