Electrical Characteristics; Duty Cycle - Multimetrix CM603 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

The uncertainties are expressed in % of the reading (R) and in number of
display points (pt): ±(a% R + b pt)

3.2. ELECTRICAL CHARACTERISTICS

3.3.1. VOLTAGE
DC range
Resolution
Intrinsic
uncertainty
Input
resistance
For AC measurements, the frequency is between 40 and 400Hz and the signal
is sinusoidal.
AC range
Resolution
Intrinsic
uncertainty
Input
resistance
3.3.2. FREQUENCY
Measurement range: 10Hz to 10kHz.
Overload protection up to 600 Vac.
Input voltage ≥ 2 V
Range
Resolution
Intrinsic uncertainty

3.3.3. DUTY CYCLE

Measurement range
Resolution
Intrinsic uncertainty
3.3.4. CURRENT
The frequency is between 50 and 60Hz and the signal is sinusoidal.
Maximum current: 120% of the range for less than 60 seconds.
AC range
Resolution
Intrinsic
uncertainty
3.3.5. RESISTANCE
Open-circuit voltage: approximately 0.4 V
Range
400W
4kW
40kW
400kW
4MW
40MW
4V
1mV
4V
1mV
. This voltage increases with the frequency to be measured.
ac
40A
10mA
Resolution
0,1W
1W
10W
100W
1kW
10kW
40V
10mV
±(0.8% R ±3 pt)
10MΩ
40V
10mV
±(1% R ±5 pt)
10MW
100 Hz
0,01 Hz
± (1% R ± 5 pt)
0.1-99.9%
0.1%
±2%
400A
100mA
±(2.5% R ±5 pt)
.
dc
Intrinsic uncertainty
±(1% R ±5 pt)
±(2% R ±5 pt)
13
400V
100mV
400V
100mV
1 kHz
0,1 Hz
600A
1A
600V
1V
600V
1V
10 kHz
1 Hz

Publicidad

Tabla de contenido
loading

Tabla de contenido