3  Design of vacuum/pressure switch
1
UP BUTTON
2
Display
3
DOWN BUTTON
4
SET BUTTON
5
Electrical connection/con-
nection cable
6
Measuring medium
7
O-ring
8
Mounting thread 2xM5
4  Pneumatically Connecting the Switch
4 The pneumatic connection uses a G1 or G2
thread. Connect suitable pipelines with the appro-
priate connection. To connect the hex socket or
connector, hold the hexagonal part of the pneu-
matic connector tight and secure it. Use a tighten-
ing torque of 13 Nm or less.
10 / 40
2
1
4
3
8
7
EN-US · 30.30.01.02016 · 01 · 11/19
5
6