Wire connections shown in Fig. 1 are described hereunder:
Terminals
Function
M+/M-/
+ENC/OUT/
Motor
-ENC
BAR/BAR
SAFETY EDGE
CLOSE
CLOSE
OPEN
OPEN
PHOT
Photocell
STOP
STOP
P.P.
Step by step
+COM
COMMON
SHIELD/
antenna
ANT
FAST
24V
Secondary
SLOW
Transformer
0V
+ 24V -
24 Vac/dcs
BLINK
Flashing
SCA or Service
SCA
light
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and
setting the desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the
software release.
USE OF PROGRAMMING KEYS
Press <PG> key to gain access to the Main Menu (PAR>>LOG>>RADIO>>...). These keys can be selected by pressing +
and – keys.
Select the Main menu with <PG> key to enter the desired Function Menu .
• If <+> is pressed, the Function Menu can be scrolled from top to bottom.
• If <-> is pressed, the Function Menu can be scrolled from bottom to top.
• If <PG> key is pressed, presetting to be modified can be entered.
• The preset values can be modified by using <+> and <-> keys.
• The value is programmed if <PG> key is pressed again. The word "PRG" appears on the display.
See paragraph "Programming Example"..
NOTES:
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without mak-
ing any changes.
CONTROL PANEL CP.J4

WIRE DIAGRAM

Description
Encoder and motor plug
Input, sensitive safety edge
8K2 resistive safety edge: "DAS" jack closed (weld between contacts)
Mechanical edge : "DAS" jack open (default)
When the safety edge is activated, the gate leaf stops and movement is reversed for
about 3s.
Input, CLOSE push-button (Normally Open contact).
Input, OPEN push-button (Normally Open contact).
Input, photocell is activated in the closing phase. It can be configurable with PH C
logics.
STOP button input (N.C. contact)
STEP BY STEP input ( N.O. contact)
Common for all control inputs.
Connection antenna to the built-in receiver
SHIELD: Screen / ANT: Signal
Secondary winding of the transformer.
FAST: Motor normal speed
24V: 23V output
SLOW: 15V slow down speed
0V: 0V output
Accessories power supply 24Vac/0,5A max.
Warning: With the backup battery card CB.24V, the output (without mains) is 24Vdc
(polarized).
Check devices connection polarity.
Connection to flashing light 24Vdc 15W max.
24VAC/DC output, configurable as SCA (open gate light) or timed Service light (see
SERL Logics). During the operation with buffer battery, it features a polarised 24VDC
voltage.
PROGRAMMING
13