1)
PC 2000 Instrument
2)
Flow regulating valve
3)
Temperature Probe
4)
pH Probe
5)
Redox Probe
6)
Panel Support
7)
4X6 Water Outlet
8)
4X6 Water sample intake
9)
Drawing off tap and chlorine probe outlet
10)
4X6 Water sample intake
11)
Flow sensor
12)
Graduated flow meter
13)
Filter
14)
Channel
15)
Tool holder pocket
16)
Cable for pH pump
17)
Cable for Chlorine pump
18)
Power supply cable for the PC2000 instrument.
Panel
Dimensions:
Weight:
Sample intake:
Sample outlet:
Flow regulator:
Flow alarm:
Chlorine measuring cell
TECHNOLOGY:
ELECTRODES:
CLEANING:
CALIBRATION:
pH Measurement
Electrode: SPH-1-S-1,5 0..14pH 3 BAR 60 °C
Electronic instrument
Model: PC2000
Measurement: Ph 0..14, Chlorine 0...5 ppm, °C 0..125
Regulation:
Outputs:
Calibration:
Power Supply:standard 230V ± 10% 50-60 Hz
Accessories
pH Solutions:
Optional Extra
Temperature sensor: PT100 in glass 12*160mm
PARTS DESCRIPTION
(H x W x D) 600 x 700 x 10 mm
8 kg
4X6
4X6
with variable area 5 lit/h, 60 lit/h
reed contact in absence of flow
SELF-CLEANING AMPEROMETRIC
PLATINUM - COPPER
WITH 200 GLASS SPHERES
semi-automatic, with DPD comparison
On/Off, Standby/Work, impulse proportional, current proportional
relay/ mA/ impulses
pH, Chlorine, self calibrating
7.00, 4.00 pH at 20 °C 90ml
TECHNICAL DATA
4