23. SUMMARY DRAW PROBLEMS, CASUSES AND SOLUTIONS
ANOMALIES
pH level below programmed value (if
an increaser is used).
pH level above programmed value (if
an reducer is used).
Chlorine/Bromine
level
programmed value.
Chlorine/Bromine
level
programmed value.
Led which indicates connection to the
pH or Cl/Br measuring pump or
motorised valve (activated), when the
corresponding measuring pump is not
measuring or when the motorised
valve is not open.
Motorised valve is not open and relay
doesn't work.
Physicochemical
analysis
swimming
pool
water,
particularly
Cl/Br and pH level do not correspond
to the Control reading (there is a big
difference).
pH and/or mV reading in the LCD
screen twinkle.
23. TECHNICAL SPECIFICATIONS OF CONTROL-MINOR
- pH measure rank: 0 to 14 (resolution: 0.1 unit).
- pH Set Point rank: 6.2 to 7.8.
- mV measure rank: 0 to 1999 (resolution: 1 mV).
- Set Point potential Redox rank: 500 to 900 mV.
- Delay: 10 seconds.
- Calibration to pH 7 and pH 4.
- Outfit electric demand: 500W.
CAUSES
You have selected a % of the
measuring pump higher than suitable.
You have selected a % of the
measuring pump higher than suitable.
above
C. Minor Inorganic Cl(Version A): The
chlorine measuring pump has a %
higher than suitable.
C. Minor Organic Cl/Br (Version B
and C): Inlet valve of water into the
tablets doser is too open or tablets
load inside the doser is too big.
below
C. Minor Inorganic Cl(Version A):
The chlorine measuring pump has a %
higher than suitable.
C. Minor Organic Cl/Br (Version B
and C): Inlet valve of water into the
tablets doser is partially open or
tablets load inside the doser is small.
a)
Plugs 2 and 5 of the terminal strip are
not connected with a free tension
contact of the filtering pump contactor
(see page 12 ).
b)
Stopped filtration.
Wrong connection.
of
the
a)
Dirty cartridge filter (see pages
13-14, point 4).
b)
Dirty probes.
c)
Exhausted electrodes.
pH and/or mVprobes backlash.
14
SOLUTIONS
Reduce
%
adjusting
it
characteristics of the swimming pool.
Reduce
%
adjusting
it
characteristics of the swimming pool.
C. Minor Inorganic Cl(Version A):
Reduce
%
adjusting
it
characteristics of the swimming pool.
C. Minor Organic Cl/Br (Version B):
Close part of the inlet valve of water
into the doser or decrease tablets load
inside.
C. Minor Inorganic Cl(Version A):
Increase
%
adjusting
it
characteristics of the swimming pool.
C. Minor Organic Cl/Br (Version B):
Open more the inlet valve of water into
the doser or increase tablets load
inside.
a)
Connect terminal strips plugs 2 and 5
with a free tension contactor in the
filtering pump.
b)
If the filtration is in automatic mode,
wait until it starts according to the
fixed hour, or use the filtration in
manual mode.
Electrical connection check-up (see
diagrams page 10).
a)
Clean.
b)
Clean them with cleaning
solution.
c)
Change them.
Calibrate again.
Ref.16642R0100-gb-R04