Measure your weight
You can also measure your weight without selecting a user.
• Switch the scale on until '0.0 kg' appears. Now stand on the scale. An acoustic signal sounds. The display '0.0 kg' starts to
fl ash.
Stand still on the scale with your weight evenly distributed over both legs. When the measurement is complete, the result is
displayed (a) but it is not allocated to a memory number.
Switch the scale off
After the measured result is displayed, for several seconds 2 acoustic signals are emitted from the scale platform and the scale switches off automati-
cally. Alternatively, you can switch the scale off by pressing the ON/OFF button.
6. Memory function
The Veroval
scale stores up to 30 measurements for each user memory number. The oldest measured value is always at memory position number 1
®
and all newer stored values shift up by one memory position. Once all memory slots are occupied, the oldest value is deleted.
To retrieve the saved measurements, work through the following steps:
Select the user memory number
• Press the UP button r. On the display P1 (a) appears. Within 1.5 seconds, select the user memory number for which you would like to retrieve the
saved measurements using the UP button r or the DOWN button s. If you do not press any button, the previously selected user memory number
remains.
• After 1.5 seconds, the ideal weight (b) corresponding to your user data appears briefl y on the display.
On the display 0. 0 (c) appears.
Select the measured value memory position
• Press the DOWN button s. On the bottom left of the display (d) an [M] (e.g. 04) appears and the last measured value (e.g. 04).
(a)
(b)
Along with your weight, your BMI, body fat, body water, muscle percentage, bone mass and active metabolic rate in kcal appear one after the other
at intervals of 2 seconds.
• Press the DOWN button s again within 10 seconds to retrieve the previous measures values.
Delete measured value
• To delete the currently displayed measured value, press the SET button in the memory function. 'dEL' and 'YES' (e)
appear on the display. Confi rm the delete process by pressing the SET button again.
Restore the factory default settings
Remove the batteries in the control unit, then simultaneously press the SET and UP buttons and reinsert the batteries.
7. Transfer measured values to Veroval
Download the Veroval
®
medi.connect software from the website www.veroval.info. Compatible with any computer with Windows 7, 8 or 10 (for the
duration of offi cial Microsoft support).
Start the program and connect the Veroval
software.
No data can be transferred during a measurement.
'
' appears on the display of the control unit.
Start the data transfer using the 'medi.connect' software. Successful data transmission is shown on the display of the control unit with 'PASS'.
(c)
(d)
medi.connect
®
scale to your PC using the enclosed USB cable. Then follow the instructions in the Veroval
®