6. DRUM ATTACHMENT.
7. HOSE FOR DRUM ATTACHMENT WITH PUMP
BODY.
8. SUCTION HOSE FOR DRUM APPLICATION.
9. SUCTION / DISCHARGE HOSE.
10. STRAINER.
11. DELIVERY NOZZLE.
3
7
1
2
11
9
10
WARNING: Remove the pump from its pac-
kaging and carefully examine it. Do not discard
the packaging until all parts have been exami-
ned.
PUMP OPERATION
1. Remove the Pump Body from the pack.
Pump body has 4 mounting holes. Mount the
body using these holes & screws. The body can
be mounted in any direction, upside down,
vertically, horizontally, etc.
2. Top of the Pump Body has the Lever mecha-
nism. Position of the lever handle can be chan-
ged, depending where the pump is mounted.
The lever mechanism is fitted onto the body
by means of a bayonet connection. Turning it
anti-clockwise will open the connection. Adjust
handle position , fit it back & lock by turning in
the clockwise direction.
3. The Pump body has 2 ports, clearly marked
as IN & OUT. Cut the suction / discharge hose
supplied in 2 parts, one for the suction end and
the other for discharge. Slide the Suction & Dis-
charge hoses onto these ports & tighten using
hose clamps.
4. Strainer may be used on the other end of
the Suction Hose & fitted with the hose using
6
4
5
6
8
E N G L I S H •
hose clamps.
5. Connect the other end of the Discharge Hose
with the Delivery Nozzle using hose clamps.
6. The pump is now ready for use.
7. By simply moving the lever handle up &
down, pumping will start in a few strokes.
Effort required to pump varies & is based on
the media being pumped. Pump is designed
for use with low viscosity media. If used with
thick media , effort required will increase.
8. After pumping is completed, it is a good
practice to open the pump & clean using water.
Pump can be opened by simply turning the
lever handle in anti clockwise direction.
USING THE PUMP WITH A DRUM
1. Remove the Pump Body & the Drum Atta-
chment from the pack. Drum Attachment has
two ports at right angles to each other. The
port extending from the 2" Drum threads is
the inlet port & the other is the Outlet Port.
Align the pump body & the pump attachment
such that the outlet port of the Drum.
Attachment is on the same side as the IN port
of the pump body. Now connect the pump
body & drum attachment using the 4 screws.
2. Connect the Outlet Port of the Drum Attach-
ment with the IN port on the pump body using
the 0.5 m hose for drum attachment & 2 hose
clamps.
3. Connect the Suction hose for Drum applica-
tion to the INLET port on the drum attachment
using a hose clamp. The other end of the hose
maybe connected to the strainer using hose
clamp.
4. Now install the assembled pump onto the
drum. Drum attachment has threads for use
with both metal & plastic drums. Tighten it
fully onto the threaded opening on the drum.
5. Top of the Pump Body has the Lever me-
chanism. Position of the lever handle can be
changed, depending upon where the pump is
mounted. The lever mechanism is fitted onto
the body by means of a bayonet connection.
Turning it anti-clockwise will open the connec-
tion. Adjust handle position , fit it back & lock
by turning in the clockwise direction.
6. Slide the Suction/ Discharge hose onto the
OUT port marked on the pump body & tighten
using hose clamps.
7. Connect the other end of the Suction / Dis-
U s er 's m anual