4-times option for torch trigger.
Permit to define 3 different ways
to control the torch trigger when the
machine is set as 4Times stroke (Lift or
HF). For detailed description of different
behaviours see the following diagrams.
Select a value in the range 0...2 (1=default
setting).
Dynamic Oxide Control
(for AC welding)
0 = disabled
1 = enabled (factory settings)
Remote Control Option
It is possible to select 4 different
ways depending from the external device
connected to 8-pole plug(option)
Welding current can be controlled up to
previous SET or to MAX.
External reference voltage can be 0-10V or
0-5V (Condition 2 & 3 presents lower
resolution)
0 = 0-10V
1 = 0-10V
2 = 0-5V
3 = 0-5V
All above settings are not modified via Reset.
Imin to ISET (factory settings)
Imin to IMAX
Imin to ISET
Imin to IMAX
26