Console (fig. E)
CAUTION
Keep the console away from direct sunlight.
Dry the surface of the console when it is covered
with drops of sweat.
Do not lean on the console.
Only touch the display with the tip of your finger.
Make sure that your nails or sharp objects do not
touch the display.
NOTE
The console switches to standby mode when the
equipment is not used for 4 minutes.
In standby mode, the console software is
displayed.
Explanation Display functions
Dot Matrix
-
Dot matrix will show programming information
during setting up your training program.
-
In Manual mode, dot matrix will show training
intensity and progress.
-
In Training mode, Dot matrix will be divided in a
upper computer section to show the SPM simulation
of your set target, and lower user section to show
the user (player) active SPM performance.
-
In Race mode the Dot matrix will be divided in a
upper computer target distance track, and a lower
section to show the user (player) target distance
track. Both tracks will fill equal to the distance
counting down.
Time
-
Without setting the target value, time will count up.
-
When setting the target value, time will count down
from your target time to 0 and alarm will sound or
flash. (During countdown "Remaining" is shown )
-
Without any signal being transmitted into the
monitor for 4 seconds during workout, time will
STOP
-
Range 0:00~99:59 /± 1:00
Distance
-
Without setting the target value, distance will count
up.
-
When setting the target value, distance will count
down from your target distance to 0 with an alarm
sound or flash. (During countdown "Remaining" is
shown )
-
Range 0.00~99.99 /± 100
Calories
-
Without setting the target value, calorie will count
up.
-
Range 0~9999.
NOTE
This data is a rough guide for comparison of
different exercise sessions which cannot be used
in medical treatment
Level
Console level should match the mechanical resistance
level for the most accurate data reading.
Setting the correct level will affect the data for: "Time/
500M", "Distance", "Calories", "Speed" and "Watt"
readings.
NOTE
Make sure you match the console tension level
with the mechanical tension setting always.
Heart rate
-
Current pulse will display after 6 seconds when
detected by the console.
Stroke
-
Without setting the target value, strokes will count
up.
-
When setting the target value, strokes will count
down from your target distance to 0 with an alarm
sound or flash. (During countdown "Remaining" is
shown )
-
Range 0 ~99999 /± 10
Watt
-
Shows workout watt power during exercise.
-
Ahead is showing number of meters ahead on
computer when finish Race mode.
-
Behind is showing number of meters behind on
computer when finish Race mode.
Speed
-
Shows actual speed during exercise in KM/H
-
Range: 0.0 ~ 99.9
-
Shows "AVG" avarage speed when being in
"Pause" mode.
SPM
-
SPM is Strokes Per Minute and is showing the
avarage Strokes per minute during workout.
-
In "Training Mode" this can be set as target in range
20~80.
Time/ 500M
Shows the time needed to run a 500 meter distance
workout, based on the current rowing intensity.