Repairs

Repairs under warranty are carried out by the manufacturer. Repairs outside the warranty period
should only be carried out by skilled technical personnel. Failure to observe the assembly and
setting procedures and operation by non-skilled personnel may result in serious damage to the
riveting tool. In case of doubt, always send in the device to the manufacturer.
Regular maintenance will extend the service life of your high-quality GESIPA
tools and they should be serviced at least every 2 years by an authorised
workshop or by GESIPA
we recommend servicing ahead of schedule.
12.

Troubleshooting

12.1

Blind rivet is not set

Cause
Jaws (No. 4) dirty
Jaws (No. 4) worn
Insufficient compressed air
12.2

Spent mandrel is not conveyed automatically into the container

Cause
Wrong nosepiece used (No. 1)
Nosepiece (No. 1) worn
Spent mandrel jammed in jaw housing
(No. 3)
Spent mandrel container full
Wrong jaw pusher (No. 5) used
Service. For tools that are subject to intensive use,
®
Remedy
Clean and oil sliding surfaces (see 10.1)
Replace (see 10.1)
See operating pressure (see 3.)
Remedy
Replace according to table (see 6.)
Replace
Clean or replace jaw mechanism (see 10.1)
Empty (see 9.)
Replace according to table (see 6.) and
refer to Section 10.1