Technical Specifications
Technical Specifications
Film transport:
Film formats:
Processing capactiy:
Process time:
Linear speed:
Developer time:
Tank capacities:
Circulation system:
Replenishment:
Developer temperature:
Fixer temperature:
Water connection:
Water consumption:
Drain capacity:
Noise level:
Heat emission:
Environmental condi-
tions:
Pollution degree:
System protection:
10
Continuous roller transport system
In general: sheet films up to max. 35.8 cm
(14.1'') width;
Smallest film format 10x10 cm (4x4 '').
74 films 24x30 cm (10x12 ") per hour (standard
model, feed film crosswise)
Standard 105 s
Standard 37 cm/min. (14.5 in/min)
Standard 29 s
Developer, fixer 2.3 litres each (0.51 gal) and
water tank 2.1 litres (0.46 gal)
Developer and fixer are continiuously circulated by
a circulation pump
Automatic replenishment by film detection, in rela-
tion to film length
Ex works set to 32 °C (89.6 °F)
In exceptional cases can be set by a technician
Adjusted to developer temperature by heat
exchanger.
Permissible water pressure 2 - 10 bar (29 - 145
psi), permissible water temperature 5 - 30 °C (41 -
86 °F).
1.0 litres per minute (0.26 gal/min) when process-
ing.
7 litres per minute (1.85 gal/min).
Less than 60 dB(A).
Operation: 0.1 kJ/s,
Development: 1.1 kJ/s
1) Temperature 18 - 40 °C (51.6 - 104 °F), venti-
lated room, room temperature should be lower
than set bath temperature.
2) Relative humidity lower than 80% up to 31 °C
(80 °F), linearly decreasing to 50% at 40°C
(104°F)
3) Height above sea level less than 2000 m (6666
ft.)
4) Indoor use
2
IP 20
ECOMAX
TM