Minimum distance from cooking appliance
Optimum extraction performance is achieved when the hood is mounted at a height of
at least 550 mm from the top edge of the worktop. For gas, it is also min. 650mm. In
order to prevent condensate formation, a backwater flap must be mounted directly on
the outside of the air outlet. For gas cooking appliances, the applicable installation re-
gulations and the installation instructions of the gas appliance manufacturer must be
observed. The cooker hood may only be installed above gas cooking zones at a mini-
mum distance of 650 mm if the following nominal heat loads (Hs) are not exceeded:
Gas stoves
Load from one gas ring max.3.0 kW
Load from all gas rings max.8.3 kW
Load from oven max.3.9 kW
Gas hobs
Load from one gas ring max.3.9 kW
Load from all gas rings max.11.3 kW
Spacing:
Max. room height 2,7m
With the C - circulating air version, air turbulence can occur at high fan speeds. We
therefore recommend a minimum distance of 2m between recirculation openings and
walls!
Connection to power supply
Check that the rated voltage of the device corresponds to the local mains voltage. In-
correct setting will damage or destroy the device.
Before operation, check whether all cables and wires are faultless and undamaged. In
particular, make sure that the cables have no kinks, have not been laid too short
around corners and that there are no objects on the cables. Furthermore, make sure
that all plug connections are tight. Faulty shielding or wiring endangers your health
(electric shock) and can destroy other equipment. Devices with a mains plug are
equipped with a safety-tested mains cable from the country of use and must only be
connected to a properly earthed earth contact socket, otherwise there is a risk of
electric shock. Make sure that the socket at the device or the earth contact socket of
the house installation is freely accessible so that the mains cable can be disconnected
from the socket in an emergency or during service or maintenance work.
Transport, unpacking, installation
Condensation may occur if the appliance is brought into the instal-
lation site from a cold environment. Please wait until the appliance
has adjusted to the temperature and is completely dry before ope-
rating it. The acclimatization period depends on the temperature
difference and the type and design of the appliance. However, it
should be at least 12 hours.
Please wear protective gloves during installation to avoid the risk
of injury. Prepare the necessary tools before mounting the hood.
For the installation of the hood, on-site requirements must be met
to ensure smooth installation of the hood and kitchen appliances
must be covered.
Prepare a suitable exhaust air duct in the ceiling, open the false
ceiling, create openings, etc..
Before drilling in the wall, make sure that no pipes behind it are da-
maged.